Kano
|
89d0062ac8
|
bflsc increase flush count to handle parallel work
|
2013-07-08 19:41:23 +10:00 |
|
Kano
|
a9e10988ed
|
force type checking on curses
|
2013-07-06 22:08:17 +10:00 |
|
Kano
|
5fb5dd0bd6
|
logging - size check sprintf
|
2013-07-06 21:04:32 +10:00 |
|
Kano
|
51a928fe7e
|
usbutils - size check all sprintf
|
2013-07-06 20:56:50 +10:00 |
|
Kano
|
74d71cce2c
|
cgminer - size check all sprintf
|
2013-07-06 20:47:49 +10:00 |
|
Kano
|
ad1572f77f
|
size check get_datestamp/get_timestamp and remove unused cgpu->init
|
2013-07-06 20:17:17 +10:00 |
|
Kano
|
385a70bea7
|
make all statline overflow safe
|
2013-07-06 19:15:59 +10:00 |
|
ckolivas
|
805672fb51
|
More GPU READMEs.
|
2013-07-05 21:40:30 +10:00 |
|
kanoi
|
fa41f31b18
|
Merge pull request #461 from kanoi/master
WU only needs +2 width
|
2013-07-05 01:35:28 -07:00 |
|
Kano
|
df05174e1d
|
WU only needs +2 width
|
2013-07-05 18:26:18 +10:00 |
|
Con Kolivas
|
a011fe5182
|
Check for a timeout in avalon_scanhash and post to the write sem if we receive one.
|
2013-07-03 22:40:47 +10:00 |
|
Con Kolivas
|
3b2f9ccb88
|
Decay result count in avalon more slowly to not falsely detect idle periods as low result return rates.
|
2013-07-03 21:48:06 +10:00 |
|
Con Kolivas
|
4b4a13549e
|
Count the number of miners idled in avalon to account more accurately for when its result return rate is too low.
|
2013-07-03 21:22:27 +10:00 |
|
Con Kolivas
|
e13c580cac
|
Fix potential dereference when starting avalon with all new work.
|
2013-07-03 20:56:56 +10:00 |
|
Con Kolivas
|
42d96ee7fe
|
Convert the decay_time function into one that truly creates an exponentially decaying average over opt_log_interval.
|
2013-07-02 20:41:44 +10:00 |
|
Con Kolivas
|
18422fbf7d
|
Only throttle avalon clockspeed in avalon_auto in non optimal temperature settings if the fanspeed has reached maximum.
|
2013-07-02 16:07:32 +10:00 |
|
Con Kolivas
|
3ef0db5658
|
Reinstate more aggressive <2% HW error target for avalon-auto
|
2013-07-02 09:02:40 +10:00 |
|
Con Kolivas
|
2a1ff962ee
|
Add more information about avalon-fan and avalon-freq to ASIC-README
|
2013-07-01 17:57:24 +10:00 |
|
Con Kolivas
|
05344eff03
|
Set avalon fan min and fan max to PWM values instead of percentage.
|
2013-07-01 16:20:41 +10:00 |
|
Con Kolivas
|
065b6a5e36
|
Provide an --avalon-freq command line to give a valid range of frequencies for avalon in auto mode.
|
2013-07-01 15:38:15 +10:00 |
|
Con Kolivas
|
36b556aa66
|
Set the avalon idle frequency to lowest if avalon auto is enabled and we have an overheat condition.
|
2013-07-01 15:15:36 +10:00 |
|
Con Kolivas
|
ce214e1270
|
Decrease avalon frequency in auto mode if we are unable to maintain the temperature in the optimal range.
|
2013-07-01 15:10:56 +10:00 |
|
Con Kolivas
|
da680f5162
|
Don't count invalid nonces as hashrate for bflsc.
|
2013-07-01 14:44:27 +10:00 |
|
Con Kolivas
|
d7c99cd116
|
Use a more conservative upper limit of 1% for hardware errors with avalon auto frequency.
|
2013-07-01 10:43:33 +10:00 |
|
Con Kolivas
|
f142a4de23
|
Allow the avalon fanspeed range to be passed as parameter on the command line, default to 20-100%
|
2013-07-01 10:41:22 +10:00 |
|
Con Kolivas
|
1b81ecf932
|
Just display A: and R: for difficulty accepted and rejected to preserve screen real estate and decrease decimal places for WU.
|
2013-06-30 15:51:46 +10:00 |
|
Con Kolivas
|
99b219f99d
|
Merge pull request #460 from kanoi/master
Update all screen A/R to instead use DA/DR and device U to WU
|
2013-06-28 15:49:33 -07:00 |
|
Kano
|
a94b7be3bc
|
correct device DR: and remove global U:
|
2013-06-29 08:41:22 +10:00 |
|
Kano
|
800dc24916
|
Update all screen A/R to instead use DA/DR and device U to WU
|
2013-06-29 01:43:18 +10:00 |
|
kanoi
|
21624df372
|
Merge pull request #459 from kanoi/master
miner.php add ASC fields
|
2013-06-28 07:13:24 -07:00 |
|
Kano
|
e76e5afca6
|
miner.php add ASC fields
|
2013-06-29 00:12:29 +10:00 |
|
kanoi
|
a5437f182f
|
Merge pull request #458 from kanoi/master
GPU fan rpm display 9999 when it overflows
|
2013-06-28 06:32:31 -07:00 |
|
Kano
|
2d8cc36b82
|
GPU fan rpm display 9999 when it overflows
|
2013-06-28 23:19:09 +10:00 |
|
kanoi
|
951ec31142
|
Merge pull request #457 from kanoi/master
bflsc get volts stats needs its own GETVOLTS
|
2013-06-28 05:58:45 -07:00 |
|
Kano
|
2beb30f13d
|
bflsc get volts stats needs its own GETVOLTS
|
2013-06-28 22:55:55 +10:00 |
|
kanoi
|
4e16560749
|
Merge pull request #456 from kanoi/master
cps and usbdev locking
|
2013-06-27 04:59:58 -07:00 |
|
Con Kolivas
|
34547596b3
|
Support all avalon frequencies on the command line.
|
2013-06-27 08:26:53 +10:00 |
|
Con Kolivas
|
862c88ecbb
|
Move to slightly more relaxed timeouts for avalon.
|
2013-06-27 07:52:51 +10:00 |
|
Kano
|
c8a647edeb
|
MMQ turn on cps delays
|
2013-06-27 00:41:10 +10:00 |
|
Kano
|
e8bbb49b5b
|
bflsc x-link header different to documentation
|
2013-06-27 00:39:25 +10:00 |
|
Con Kolivas
|
18f9112e48
|
Reset the other auto counters in avalon when idling a device.
|
2013-06-26 21:46:58 +10:00 |
|
Kano
|
9ecef180d1
|
usbutils/icarus include more locking to usbdev access
|
2013-06-26 12:53:05 +10:00 |
|
Kano
|
5676758594
|
Icarus turn on cps delays by default
|
2013-06-26 11:50:56 +10:00 |
|
Kano
|
1f4b99d0e9
|
usbutils cps correct time measurement
|
2013-06-26 01:12:01 +10:00 |
|
Con Kolivas
|
9f15a08f2a
|
Bump version number to 3.3.1
|
2013-06-26 00:17:22 +10:00 |
|
Con Kolivas
|
12c1492279
|
Update NEWS.
|
2013-06-26 00:17:03 +10:00 |
|
Con Kolivas
|
e811c4dc77
|
Add an avalon-auto option which enables dynamic overclocking based on hardware error rate for maximum effective hashrate.
|
2013-06-26 00:15:04 +10:00 |
|
Kano
|
fc89f170a3
|
usbutils add delay API stats
|
2013-06-25 22:23:06 +10:00 |
|
Kano
|
527c6ee255
|
usbutils optional cps IO control - but not enabled
|
2013-06-25 21:35:21 +10:00 |
|
Con Kolivas
|
9b45daba6b
|
Add an --avalon-cutoff feature which puts the avalon idle should it reach this temperature, defaulting to 60, re-enabling it when it gets to target temperature.
|
2013-06-25 19:39:42 +10:00 |
|