Browse Source

Add more information about avalon-fan and avalon-freq to ASIC-README

nfactor-troky
Con Kolivas 12 years ago
parent
commit
2a1ff962ee
  1. 14
      ASIC-README

14
ASIC-README

@ -98,6 +98,20 @@ around 1% is achieved. This WILL run your avalon beyond its normal specification
so the usual warnings apply. When avalon-auto is enabled, the avalon-options so the usual warnings apply. When avalon-auto is enabled, the avalon-options
for frequency and timeout are used as the starting point only. for frequency and timeout are used as the starting point only.
eg:
--avalon-fan 50
--avalon-fan 40-80
By default the avalon fans will be adjusted to maintain a target temperature
over a range from 20 to 100% fanspeed. avalon-fan allows you to limit the
range of fanspeeds to a single value or a range of values.
eg:
--avalon-freq 300-350
In combination with the avalon-auto command, the avalon-freq command allows you
to limit the range of frequencies which auto will adjust to.
eg: eg:
--avalon-temp 55 --avalon-temp 55

Loading…
Cancel
Save