Author SHA1 Message Date
Con Kolivas
eeac9d81fc Replace all references to the old n*sleep functions with the equivalent cgsleep_*s replacements. 2013-08-20 19:23:49 +10:00
Con Kolivas
bedd8eeead Revert "Sleep for half a work period only in bflsc_get_results if no dev is suitable."
This reverts commit 9743194547.

Fine now that sleep works properly with the longer sleep.
2013-08-19 21:52:07 +10:00
Con Kolivas
fb66e8b7b7 Only grab a queued work item if we successfully grab the lock to submit work in bflsc_send_work 2013-08-19 21:13:23 +10:00
Con Kolivas
dddc2d1e60 Revert "Reuse times extracted from the clock in bflsc_get_results."
This reverts commit 1d8235334d.

Monotonic clock does not return the same times as gettimeofday.
2013-08-19 17:59:59 +10:00
Con Kolivas
1d8235334d Reuse times extracted from the clock in bflsc_get_results. 2013-08-19 17:55:32 +10:00
Con Kolivas
9743194547 Sleep for half a work period only in bflsc_get_results if no dev is suitable. 2013-08-19 16:36:01 +10:00
Con Kolivas
a61e41a070 Check for thr->work_restart in restart_wait. 2013-08-19 15:58:22 +10:00
Con Kolivas
89f571f527 We should be using que_low to decrease scan sleep time in bflsc. 2013-08-19 15:51:14 +10:00
Con Kolivas
09dbd616e2 Prepare sleep time on bflsc if no dev needs work yet to avoid busy waiting. 2013-08-19 13:57:36 +10:00
Con Kolivas
09e9091dd7 Simplify cgsleep code for windows by using a typedef for cgtimer_t that resolves to clock resolution, using that internally. 2013-08-19 13:54:56 +10:00
Con Kolivas
e56c9a5d3b Use the cgsleep reentrant function to sleep for bflsc between read results to account for time taken to perform reads. 2013-08-18 16:49:15 +10:00
Con Kolivas
3c707202cf Use 100ms delay between checking for results on all bflsc devices as the buffering of results mean checking more frequently just wastes CPU and causes more lock contention for only marginally better latencies. 2013-08-18 16:46:27 +10:00
Con Kolivas
d71e9f91f4 Add a --bflsc-overheat command which allows you to set the throttling temperature for BFLSC devices or disable it. 2013-08-09 06:43:25 +10:00
Con Kolivas
812852cc36 Move bflsc defines to a header file. 2013-08-09 06:31:57 +10:00
Kano
18e4edc776 bflsc nonce per work item stats 2013-07-08 20:28:03 +10:00
Kano
89d0062ac8 bflsc increase flush count to handle parallel work 2013-07-08 19:41:23 +10:00
Kano
ad1572f77f size check get_datestamp/get_timestamp and remove unused cgpu->init 2013-07-06 20:17:17 +10:00
Kano
385a70bea7 make all statline overflow safe 2013-07-06 19:15:59 +10:00
Con Kolivas
da680f5162 Don't count invalid nonces as hashrate for bflsc. 2013-07-01 14:44:27 +10:00
Kano
2beb30f13d bflsc get volts stats needs its own GETVOLTS 2013-06-28 22:55:55 +10:00
Kano
e8bbb49b5b bflsc x-link header different to documentation 2013-06-27 00:39:25 +10:00
ckolivas
9dc2f3f175 Redo +1 fix in bflsc. 2013-06-25 11:21:28 +10:00
Con Kolivas
a7f9bf3c52 Merge pull request #454 from kanoi/master
bflsc - handle xlink timeouts by having generic IO functions
2013-06-23 15:37:00 -07:00
Con Kolivas
f5911528bf Demote bflsc hw error messages to verbose logging only. 2013-06-24 08:17:27 +10:00
Kano
f2bbfee704 bflsc - handle xlink timeouts by having generic IO functions 2013-06-23 18:14:12 +10:00
Con Kolivas
d741410f6d sc_count shouldn't be +1 in bflsc. 2013-06-23 10:13:18 +10:00
Con Kolivas
0cd2c5c3c8 Use the info timeout for read_nl in getidentify bflsc. 2013-06-23 10:12:44 +10:00
Kano
e993cf3644 bflsc try getinfo twice 2013-06-23 10:01:18 +10:00
Con Kolivas
af0ae8aa5b Decrease BAL and BAS latency to be just larger than one result read. 2013-06-19 12:09:30 +10:00
Con Kolivas
045e105dcc BFLSC latest firmware has its own thermal cutoff set to 90, so use the same value in case we have an old firmware that isn't throttling by itself. 2013-06-19 11:42:43 +10:00
Con Kolivas
7b42b83d3f Drop watermark low limits for bflsc. 2013-06-19 11:38:45 +10:00
Con Kolivas
e172c987f3 Set the fanspeed on bflsc to max if we don't know the temperature. 2013-06-19 11:29:53 +10:00
Con Kolivas
7be081d81b Use a low watermark for queueing mandatory work on bflsc instead of zero. 2013-06-19 11:24:04 +10:00
Con Kolivas
0b5eb43696 Revert "Only wait in the bflsc scanwork loop if the queues are satisfactorily filled."
This reverts commit a49969908c.

Makes the driver busy wait.
2013-06-19 10:46:28 +10:00
Con Kolivas
a49969908c Only wait in the bflsc scanwork loop if the queues are satisfactorily filled. 2013-06-19 10:40:03 +10:00
Con Kolivas
fa881badf4 Only mandatorily grab the bflsc mutex on submitting work when the queue is empty. 2013-06-19 10:22:54 +10:00
Con Kolivas
0fbd375ea3 Adjust bflsc v2 watermarks. 2013-06-19 09:43:36 +10:00
Con Kolivas
05adbbf1e9 Only increase sleep time on bflsc if the queue isn't emptying at all over the sleep duration. 2013-06-19 09:42:32 +10:00
Con Kolivas
fe1a3752b7 Fix warning. 2013-06-19 08:57:08 +10:00
Kano
a9fef661b9 bflsc yet more API stats 2013-06-19 02:50:03 +10:00
Kano
711328762f bflsc add some more API stats 2013-06-19 02:30:06 +10:00
Kano
3ac09fa2d9 bflsc correct firmware matching 2013-06-19 01:02:20 +10:00
Kano
84a5da0377 bflsc correct comment 2013-06-19 00:58:35 +10:00
Kano
8f18d4c8b0 bflsc driver support for v2 firmware 2013-06-19 00:52:13 +10:00
Con Kolivas
6d8d44c233 Fanauto on bflsc is Z9X according to the source code, not 5 as per the draft protocol document. 2013-06-17 09:57:13 +10:00
Kano
b8b137aeef USB make device_path handled by usbutils 2013-06-10 15:59:02 +10:00
Kano
749fa78d8a tidy up free in device detect functions 2013-06-10 15:39:44 +10:00
Kano
9287ee90f6 USB control creation and free of cgpu 2013-06-10 15:22:37 +10:00
Con Kolivas
24d26d9949 Throttling the BFLSC at 80 seems to prevent generating garbled responses of higher temps. 2013-06-10 02:54:18 +10:00
Con Kolivas
6fdc068f1b Revert "Give a generous timeout whenever we expect an OK message for working bflsc communications."
This reverts commit 3d8cf60b96.