Browse Source

klondike correct cvtKlnToC() temperature calculation

nfactor-troky
Kano 11 years ago committed by Con Kolivas
parent
commit
9eb7810575
  1. 12
      driver-klondike.c

12
driver-klondike.c

@ -118,7 +118,17 @@ IDENTITY KlondikeID;
static double cvtKlnToC(uint8_t temp) static double cvtKlnToC(uint8_t temp)
{ {
return (double)1/((double)1/(25+273.15) + log((double)temp*1000/(256-temp)/2200)/3987) - 273.15; double Rt, stein, celsius;
Rt = 1000.0 * 255.0 / (double)temp - 1000.0;
stein = log(Rt / 2200.0) / 3987.0;
stein += 1.0 / (double)(25.0 + 273.15);
celsius = (1.0 / stein) - 273.15;
return celsius;
} }
static int cvtCToKln(double deg) static int cvtCToKln(double deg)

Loading…
Cancel
Save